热电偶 分度号 | 补偿导线 型号 | 热电势、允差 | 热电偶 测量端 温度 | |||||
100℃ | 200℃ | |||||||
热电势 | 允差 | 热电势 | 允差 | |||||
普通级 | 精密级 | 普通级 | 精密级 | |||||
S或R | SC或RC | 645 | ±60(±5℃) | ±30(±2.5℃) | 1440 | ±60(±5℃) | - | 1000 |
K | KCA | 4095 | ±100(±2.5℃) | ±60(±1.5℃) | 8137 | ±100(±2.5℃) | ±60(±1.5℃) | 1000 |
KCB | 4095 | ±100(±2.5℃) | ±60(±1.5℃) | - | ±100(±2℃).5 | ±60(±1.5℃) | 900 | |
KX | 4095 | ±100(±2.5℃) | ±60(±1.5℃) | 8137 | ±100(±2.5℃) | ±60(±1.5℃) | 900 | |
N | NC | 2774 | ±100(±2.5℃) | ±60(±1.5℃) | 5912 | ±100(±2.5℃) | ±60(±1.5℃) | 900 |
NX | 2774 | ±100(±2.5℃) | ±60(±1.5℃) | 5912 | ±100(±2.5℃) | ±60(±1.5℃) | 900 | |
E | EX | 6317 | ±200(±2.5℃) | ±120(±1.5℃) | 13419 | ±200(±2.5℃) | ±100(±1.5℃) | 500 |
J | JX | 5268 | ±140(±2.5℃) | ±85(±1.5℃) | 10777 | ±140(±2.5℃) | ±85(±1.5℃) | 500 |
T | TX | 4277 | ±60(±1.0℃) | ±30(±0.5℃) | 9286 | ±90(±1.5℃) | ±48(±0.8℃) | 300 |
补偿导线型号 | 在20℃时往复电阻值(Ω/m) | ||||
0.2mm² | 0.5mm² | 1.0mm² | 1.5mm² | 2.5mm² | |
SC或RC | 0.25 | 0.10 | 0.05 | 0.03 | 0.02 |
KCA | 3.5 | 1.40 | 0.70 | 0.47 | 0.28 |
KCB | 2.6 | 1.04 | 0.52 | 0.35 | 0.21 |
KX | 5.50 | 2.20 | 1.10 | 0.73 | 0.44 |
EX | 6.25 | 2.50 | 1.25 | 0.83 | 0.50 |
JX | 3.25 | 1.30 | 0.65 | 0.43 | 0.26 |
TX | 2.60 | 1.04 | 0.52 | 0.35 | 0.21 |
NC | 3.75 | 1.50 | 0.75 | 0.50 | 0.30 |
NX | 7.15 | 2.86 | 1.43 | 0.95 | 0.57 |